• head_banner

News

Features Of 3 Way Motorized Actuator Ball Valve

The 3 Way Motorized Ball Valve adopts on off type angle stroke electric actuator or regulating type angle stroke electric actuator, which is powered by AC220V, AC380V or DC24V power supply voltage, and accepts current or voltage signals (4-20mA, or 1-5VDC) from industrial automatic instrument control system The utility model can control the operation and realize the proportional adjustment or two-position switching control of the process medium. The standard spherical core has l with three-way and two-port channels. Changing the relative angle between the spherical core and the pipeline can realize different combination control of the three-way pipeline fluid Suitable for liquid, gas, steam and other media proportion regulation and control.

covna-3-way-pneumatic-ball-valve-2

Product characteristics

(1) the electric three-way internal threaded ball valve has two-seat and four-seat sealing structure, and the valve core orifice has two structural forms of l type and t type. The connection state between the valve core orifice and the pipeline opening is changed by controlling the rotation angle of the valve core Different combination control of three branches can be realized. Three-way ball valve flow capacity, can control the gas, liquid, steam, more suitable for control of high viscosity, fiber granular fluid. Also applies to sealing requirements are more stringent occasions.
(2) the two-seat sealed three-way ball valve has compact structure, beautiful appearance and good sealing performance, which can realize the switch of medium flow direction in the pipeline. It can also connect or close two channels that are perpendicular to each other.
(3) the four-seat sealed three-way Ball Valve has a beautiful appearance and a compact and reasonable structure. It can not only switch the flow direction of the medium, but also make the three channels connected with each other, and can close any channel to make the other two channels connected Flexible control lines are confluent or shunted media.
(4) The t-type spool hole can make three orthogonal pipelines connect or switch each other, and play the role of shunt or confluence; the l-type hole connects two orthogonal pipelines. Cut off another channel to change the flow direction of the medium.

Technical Parameters

Medium Air, water, steam, oil, liquid, etc End Connection Threaded, Butt Welded
Port size range DN08-DN100 Core Material Stainless Steel
Body Material Stainless Steel Voltage DC-12V, 24V; AC-24V, 120V, 240V/60Hz; 110V, 220V/50Hz
Structure 3 Way.  L port / T port Voltage Tolerance ±10%
Temperature Of Media -30~180℃ Working Pressure 1.0 / 1.6 / 2.0 / 6.4 MPa

 

ON/OFF Type Feedback: the active contact signal, passive contact signal, resistant, 4-20mA
Regulation Type Input & Output signal: DC 4-20mA, DC 0-10V, DC 1-5V
Field Operation The field, remote control switch regulation and MODBUS, PROFIBUS field bus
Voltage optional AC 110-240V 380V 50/60Hz; DC12V, DC24V, Special voltage can be customized
Protection Class IP65
Torque Range 50 to 160 Nm

 


Post time: Jul-28-2021
Leave Your Message